Condition
On a vessel of at least 1,000 HP, or in a laboratory or workshop.
Performance requirement
| Behavior | Standard |
|---|---|
| The student will: | During assessment, the student shall, at a minimum: |
|
Disassemble the pump |
follow disassembly procedure in the laboratory manual |
|
Inspect all parts for wear and deterioration |
Check the following:
|
|
Repair centrifugal pump |
replace shaft packing according to procedure in the laboratory manual replace or repair other parts as necessary to bring pump to manufacturer’s specifications |
|
Reassemble centrifugal pump |
Follow procedure in laboratory manual Adjust packing, seals and gaskets as necessary |
|
Test centrifugal pump |
Operate under load and inspect for abnormalities |
Location
Assessed in EN‑2111 Auxiliary Machinery II.
References
STCW Knowledge, Understanding and Proficiency
NVIC Tasks
- NVIC 17-14 Task 8.2.B Replace a mechanical seal or repack a pump
- NVIC 17-14 Task 9.1.A Overhaul a centrifugal pump
- NVIC 17-14 Task 9.1.B Tighten pump packing
- NVIC 18-14 Task 5.1.B Operation of centrifugal and positive displacement pumps
Lab Manual
Auxiliary Machinery II Laboratory Manual
See the Assessment Guidelines for additional specifications of behavior and standards.